CLF10 sc Free Chlorine Analyzer (Panel Only) with pHD Differential Sensor

CLF10 sc Free Chlorine Analyzer (Panel Only) with pHD Differential Sensor
สินค้า: LXV45A.99.13022
Ships within 6-8 weeks

Exclusive Self Diagnostics

The CLF10 sc and CLT10 sc analyzers leverage Hach's exclusive self diagnostics to alert users when the process has changed or the instrument needs servicing. Diagnostic features include the Cal Watch algorithm for warning of pH and chlorine calibration deviation and a non-contacting flow sensor for notification of insufficient sample flow.

No Reagent Replacement, No Waste Stream

Chlorine measurement with an amperometric analyzer, such as the CLF10 sc or CLT10 sc, does not require reagents, eliminating the need for routine reagent replacement and waste stream management.

Real-Time Process Control

The CLF10 sc and CLT10 sc analyzers allow for real-time control of disinfection processes by providing continuous readings that indicate when treatment conditions have changed.

Compatible with Hach's "Plug and Play" Digital Controllers

The CLF10 sc and CLT10 sc analyzers can be used with any Hach sc digital controller. Whether you're measuring turbidity or chlorine, you only need to learn one controller for all your water analysis measurement points. Hach sc controllers have no complicated wiring or setup procedures. Just plug in any Hach digital sensor and it's ready to use without software configuration.

EPA Compliant According to Method 334.0

In accordance with EPA Method 334.0, the CLF10 sc and CLT10 sc analyzers can be used for reporting chlorine residual measurements. Additionally, Hach has created a suite of laboratory products and methods to help with startup and quality control procedures required in Method 334.0.

มีอะไรในกล่อง

CL10 sc Panel, 1 m digital extension cable, Panel Manual, pHD Sensor Manual, Chlorine Sensor Manual.

ข้อมูลจำเพาะ

pH Monitoring Required?: with pHD Differentinal
การเชื่อมต่อสายเคเบิล: 5 pin, M12 connector
การเชื่อมต่อ สายตัวอย่าง: 1/4 in OD
การเชื่อมต่อ สายระบาย: 1/2 in ID
การติดยึด: Panel or Wall Mounting
การรบกวน: Free chlorine: monochloramine, chlorine dioxide, ozone, and chalk deposits.
Total chlorine: chlorine dioxide, ozone and chalk deposits
การรับประกัน: 12 เดือน
ขนาด: mm x 25 mm (7.68 in x 0.98 in)
  Sensor Only: 195
ข้อกำหนดกำลังไฟ (แรงดันไฟฟ้า): ไม่มี
ขอบเขตการตรวจจับขั้นต่ำ (LOD): 30 ppb (0.03 ppm)
ความเข้ากันได้ของคอนโทรลเลอร์: SC200, SC1000, SC4500. All controllers sold separately
ความแม่นยำ: Free Chlorine: ± 3 % of the reference test* (DPD) at constant pH less than 7.2 (±0.2 pH unit)
ความแม่นยำ 2: Free Chlorine: ± 10 % of the reference test** (DPD) at stable pH less than 8.5 (±0.5 pH unit from the pH at calibration)
ความแม่นยำ 3: Total Chlorine: ± 10 % of the reference test** (DPD) at stable pH less than 8.5 (±0.5 pH unit from the pH at calibration)
ความแม่นยำ 4: Total Chlorine: ± 20 % of the reference test** (DPD) at stable pH greater than 8.5
ความยาว: Sensor: 195 mm
ความยาวสายเคเบิล: 1 m (between gateway and sc controller)
ความสามารถในการทวนซ้ำ: 30 ppb or 3%, whichever is greater
คอนโทรลเลอร์: Panel only
คำอธิบาย: CLF10sc Free Chlorine Analyzer (Panel Only) with pHD Differential Sensor
ช่วง: 0 - 20 ppm Cl₂
ช่วง pH: 4 - 9
ช่วงความดัน: 0.5 bar, no pressure impulses and/or vibrations
ช่วงอุณหภูมิในการทำงาน: 0 - 45 °C
ตัวเลือก: pHD Differential Sensor
น้ำหนัก: 11.2 kg Approximately 5.5 kg (12 lbs)
Panel and empty panel-mounted components only
ใบรับรอง: CE compliant for conducted and radiated emissions:
- CISPR 11 (Class A limits)
- EMC Immunity EN 61326-1 (Industrial limits)
Additional certifications when connected to an sc controller
พารามิเตอร์: Free Chlorine
ฟิตติ้ง: USA
มี: CL10sc Panel, 1 m digital extension cable, Panel Manual, pHD Sensor Manual, Chlorine Sensor Manual.
มีอะไรในกล่อง: CL10 sc Panel, 1 m digital extension cable, Panel Manual, pHD Sensor Manual, Chlorine Sensor Manual.
วัสดุ: Corrosion-resistant materials, fully-submersible
(stainless steel, PEEK, PVC, silicon rubber and polycarbonate)
วิธีการปรับเทียบ: 1-point or 2-point (zero and slope) calibration
วิธีการวัด: Reagentless, electrochemical, three-electrode amperometric system
เวลาตอบสนอง: Free Chlorine: 140 s or less for 90% change (T90)
at a stable temperature and pH
  Total Chlorine: 100 s or less for 90% change (T90)
at a stable temperature and pH
เวลาในการสุ่มตัวอย่าง: Continuous
สภาพการเก็บรักษา: -20 °C to 60 °C dry
อัตราการไหลของตัวอย่าง: 30 - 50 L/h (7.9 - 13.2 gal/hour), Optimal is 40 L/hour (10.5 gal/hour)
อุณหภูมิตัวอย่าง: 5 - 45°C (41 - 113°F)